From ODS pilot to mantel, the Airport North checklist

Listed in writing for your Airport North home, so any quote can be compared line against line.

  1. Model, rating plate and gas type recorded
  2. Embers and decorative media reviewed against the manual
  3. Distance from furniture and curtains noted
  4. Damper, ash door and outside air openings reviewed

Where a ventless fireplace repair starts in Airport North

Useful to know whether you plan a repair in Airport North or simply want the fireplace understood.

Why a shutdown device is never bypassed

Manufacturers warn that any change to a vent-free heater or its controls can be dangerous. A pilot that keeps tripping is the safety system reporting a problem with air, pressure or the pilot itself, and disabling it removes the only warning the appliance has.

Our technicians will not bridge, pin or adjust a safety device to keep a fire going. We find the cause, repair it with listed parts and test the shutdown before leaving, and each step is entered on your service record.

A vent-free fireplace is supplemental heat

Unvented room heaters cannot be the only source of comfort heating in a dwelling, under section 621.2 of the Florida fuel gas code. Manufacturers say it in their own words. One calls its log set intended for supplemental heating, and another says its appliance must never serve as a primary heat source.

If a vent-free fireplace has been standing in for a broken furnace, our team explains why that runs against the code and the manual. The fireplace repair and the heating question sit on separate lines of your estimate.

Aftermarket blowers and heat exchangers

Adding a blower to push more heat into the room is tempting. Vent-free manuals forbid a blower insert, heat exchanger insert or any accessory not approved for the heater, and one maker explains that drafts from a blower fitted inside the fireplace may cause sooting.

Some fireboxes offer a listed blower kit mounted beneath the unit. We tell you whether yours does, and we take out an unapproved blower before any other repair, since it can undo the fix.

Leak testing after vent-free service

A leak test on the gas connections is required after installing or servicing a vent-free unit. One manual says to brush a mixture of liquid soap and water on the joints, treat bubbles as a possible leak and correct every leak at once. It also says never to use an open flame to check.

Our technicians leak test every connection they touch before relighting the fireplace, and the result goes on your service record. It is part of every repair we complete in Airport North.

Renovation dust and a running vent-free burner

Drywall sanding and floor refinishing fill a room with fine dust. One manual says not to run a vent-free heater under dusty conditions, and a firebox maker warns that heavy dust on the burner and logs increases carbon monoxide formation.

Keep the fireplace off until the dust settles and the room is cleaned. After a renovation, our technicians clean the burner, pilot and logs, then test the flame before you use it again.

Common vent-free questions in Airport North

No sales pitch here, only answers from our Airport North specialists, and a free inspection when you want one.

How big does the room need to be for a ventless fireplace?

Section 621.5 of the Florida fuel gas code limits unvented heaters to 20 Btu per hour per cubic foot of the space. Manuals also use 50 cubic feet per 1,000 Btu per hour of all appliances in the space to decide whether it is confined. We run both calculations during the free inspection.

Can a vent-free fireplace be the main heat for my home?

No. Section 621.2 of the Florida fuel gas code says unvented room heaters cannot be the only source of comfort heating in a dwelling, and the manuals describe them as supplemental heat.