Skip to content

Proudly American | Family owned

Same-day service available

(352) 675-6376 Book Online

Propane and natural gas fireplace repair in Bay Hill

Repairs with the parts your maker specifies, so the fireplace stays within its listing.

  • Licensed & insured
  • Locally run
  • Family owned and operated
  • Same-day service available
4.8 out of 5 from 736 reviews
  • Google
  • Yelp
  • Facebook

Before any work on your Bay Hill fireplace

  1. Gas valve operation and a maker-specified replacement
  2. Inlet and manifold pressure read with a manometer
  3. Blower, thermostatic switch and speed control
  4. Pilot pattern and main burner lighting checked afterward

Gas fireplace repair, explained for Bay Hill homeowners

Intermittent pilot ignition and its control module

On an intermittent pilot ignition system, usually shortened to IPI, a control module runs the start. It sparks the pilot, senses that the pilot flame is really there and only then opens gas to the main burner. When the fireplace turns off, the pilot goes out as well, which Heat & Glo's owner manual describes as normal for its IPI units.

That module needs power. The installation manual for those units calls the power cord connection required for the IntelliFire Touch ignition to work, with a battery backup for outages. The same module can lock itself out after a fault and flash an error code until it is reset.

Power, spark, flame sensing and the signal to the valve are separate steps, and our technician checks each one on a visit in Bay Hill. The estimate names the step that failed rather than listing a new module by default.

Reading the pilot flame

A pilot has a shape the maker expects, and the manuals print it. On a millivolt pilot the drawing shows which part each flame must reach, and one insert owner's manual prints its electronic pilot patterns in a figure and puts pattern and strength on the technician's yearly list.

The pattern shows a problem before it becomes a failed start. A pilot that falls short of the thermopile, or an electronic pilot that does not cover its flame rod with a steady blue flame, is already telling the story. One direct vent manual adds that the pilot flame must always be present while the fireplace is running.

At your Bay Hill home, the flame is compared with the figure for that model. Cleaning or adjustment follows the manual, and a pattern that cannot be corrected is quoted as a pilot repair.

Inlet and manifold pressure readings

Gas reaches the fireplace at the inlet pressure, and the appliance regulator sets a lower manifold pressure for the burner. The rating plate lists the range the maker allows for each. The yearly technician list in one owner's manual includes verifying both with a manometer and adjusting the regulator as required.

Pressure explains faults that look like failed parts. Low pressure appears in one maker's charts as a reason the pilot will not light, and gas supply is on its list of checks for sooting glass. One installation manual also asks for inlet pressure to be confirmed while other household gas appliances are running.

Readings are taken at the valve's test points, which are then resealed and leak-checked, as one natural vent manual describes. A low inlet reading points upstream of the fireplace and is referred on, while a good one is noted on the estimate as a supply that has been ruled out.

A gas fireplace burns gas and nothing else

The logs in a gas fireplace look real, and that tempts some owners to add something. Two vent manuals from one maker are firm. Do not use any solid fuel such as wood, coal, paper or cardboard, do not cook food or burn other objects, and use only the gas type shown on the rating plate. Heatilator adds that gasoline, lantern fuel, kerosene and charcoal lighter fluid must never go into the appliance.

The direct vent one of the pair also warns never to connect the fireplace to a private, non-utility gas well. The burner, logs and ports are built around one fuel, and anything else in the firebox is outside what the appliance is listed for.

When our technician finds paper, trash or other burned material in a firebox, it is removed as one maker's yearly task list directs for foreign objects, and the logs, ember material and burner ports are checked for anything it left behind. What that finding needs, if anything, goes on the estimate.

Before you book fireplace service in Bay Hill

Which gas fireplace brands do you work on?

We work from the model on the rating plate and the maker's own manual rather than a list of brands. If we cannot confirm the manual or the parts for your unit, we tell you before any work and note it on the estimate. Vent-free units go to our ventless gas fireplace service.

Can my fireplace be switched from natural gas to propane?

Only if the maker offers an approved conversion kit for that model, fitted by a qualified service technician. We check the plate and the manual and tell you on the estimate what your model allows.