Ventless gas log and fireplace repair in Lake Eola Heights
Vent-free logs sooting or the pilot dropping out in Lake Eola Heights? Our pros trace it, fix it and show you what changed.
- Licensed & insured
- Locally run
- Family owned and operated
- Same-day service available
What we look at on a vent-free unit in Lake Eola Heights
The ODS pilot gets the first look in Lake Eola Heights, then the burner, the logs and the room around them.
- Ignitor, electrode, cable and battery tested
- Burner ports, orifice and primary air openings cleaned
- Burner crossover from rear to front observed
- Gas connections leak tested with soap solution
How our Lake Eola Heights crew repairs vent-free units
Knowledge our Lake Eola Heights crew brings to every ventless log set and firebox.
Clubhouses, schools and care buildings with vent-free units
Assembly, educational and institutional occupancies are closed to unvented room heaters under section 621.4 of the Florida fuel gas code. That reaches buildings such as meeting halls, schools and care facilities, whatever the size of the heater.
Homeowners rarely meet this rule, although community clubhouses and small offices sometimes do. If a vent-free unit sits in a building like that, we explain the code section and recommend the next step in writing, with no pressure to book.
Side wall and ceiling distances for vent-free log sets
Beyond the mantel, a vent-free log set needs space at the sides and above. One maker's chart wants 16 inches between the side of the fireplace opening and any side wall, and 42 inches between the fireplace top and the ceiling, whether the set is its 18 inch or its 24 inch size.
Built-in shelving beside a fireplace can break the side rule without anyone noticing. We check both distances against your manual and write down any gap, along with the remedy the maker allows.
Glowing embers in the right amount
Where a maker allows glowing embers at all, they go only where it says. One log set manual places rock wool embers on the front portion of the burner only, in a single layer torn into dime-size pieces, and says the total must never exceed the amount supplied with the burner.
It also says all old loose material must come off before new embers go on. Our technicians clear the burner, reapply embers to the diagram and check the flame, and that work carries our workmanship warranty.
Primary air openings at the burner
The primary air holes on a vent-free burner let the right amount of air mix with the gas. One maker says blocked air holes create soot and asks owners to keep them clear of dust, dirt, lint and pet hair, cleaning them before each heating season.
The same manual recommends cleaning every three months while the heater is in use and a yearly inspection by a qualified service person. We clean the burner, orifice holder and pilot during service and show you what came out.
Sunken fireplaces and burner airflow
A firebox floor set below the hearth can starve a vent-free burner of air. One maker advises raising the fireplace floor in a sunken fireplace with a secure noncombustible material, to keep airflow adequate and guard against sooting.
Our technicians spot a sunken floor quickly and measure how far it sits below the opening. The raise is priced with its materials, and the burner is tested again once the floor is up.
Other work in Lake Eola Heights
-
Chimney Tuckpointing Renew failed joints while retaining sound brick. Learn more
-
Chimney Liner Installation and Relining Plan a liner around the chimney and connected fireplace. Learn more
-
Gas Fireplace Glass Replacement Replace the complete glass arrangement correctly. Learn more
-
Chimney Waterproofing Protect sound masonry with the right surface treatment. Learn more
-
Electric Fireplace Installation Plan a clean installation around the room and power supply. Learn more
-
Chimney Rebuild Rebuild the failing section with a clear plan. Learn more
Learn more about ventless gas fireplace serviceLake Eola Heights services
Before you book vent-free service in Lake Eola Heights
The inspection in Lake Eola Heights is free, and these answers help you get more from it.
How big does the room need to be for a ventless fireplace?
Section 621.5 of the Florida fuel gas code limits unvented heaters to 20 Btu per hour per cubic foot of the space. Manuals also use 50 cubic feet per 1,000 Btu per hour of all appliances in the space to decide whether it is confined. We run both calculations during the free inspection.
Can vent-free logs go in a prefab fireplace?
Only when that factory-built fireplace was tested, listed and labeled for unvented use under UL 127, as section 621.7 of the Florida fuel gas code requires. One log set manual adds that it must not go in a factory-built unit whose instructions say it was not tested with unvented logs.
Request your free estimate
Share the job details and arrange a free inspection with our local team.
- Free inspection
- No hidden fees
- Family owned and operated
Need an answer now? Call (352) 675-6376
Your request is received
Thank you. We will contact you to discuss the job and confirm an appointment.