Gas inserts installed in Lake Mann Estates fireplaces

Our Lake Mann Estates experts check that the insert, the vent and the gas supply suit your fireplace, and same-day visits are possible.

  • Licensed & insured
  • Locally run
  • Family owned and operated
  • Same-day service available
4.8 out of 5 from 736 reviews
  • Google
  • Yelp
  • Facebook

Measured at your Lake Mann Estates fireplace, priced in writing

Checked in person by our family-owned team in Lake Mann Estates and explained without jargon.

  1. Plates or insulation closing the gap around the liners at the damper
  2. Surround size, depth and overlap on the fireplace face
  3. Barrier screen front ordered with the insert
  4. Conversion notice label fixed inside the firebox

The engineering behind a gas insert in Lake Mann Estates

Field notes from our gas insert installers serving Lake Mann Estates.

Why the back of the firebox matters

Many fireboxes are wider at the front than at the back, with angled side walls and a back wall that leans forward near the top. The insert itself is a rectangular unit, so its rear corners and top have to clear those angles, which is why manuals list a rear width as well as a front width.

Our technicians measure at several points, front to back and floor to lintel, and compare every number with the manual. The face of the opening alone says little about whether an insert will slide in and sit level.

Insert vents run straight up the chimney

A built-in gas fireplace can sometimes vent sideways through a wall. An insert in an existing fireplace uses the chimney that is already there. The Supreme manual is plain about it: terminating horizontally is not allowed, and vertical terminations are measured to the top of the chimney.

That is one reason the chimney's condition and height matter so much here. If the chimney cannot carry the vent, an insert may be the wrong project, and we will say so and explain what else could work.

When a deck or addition goes in later

Clearances around the cap are set when the insert goes in, but houses change. The owner's manual lists something easy to miss: verify the termination cap's clearance to later construction such as building additions, decks, fences or sheds.

For an insert venting through a chimney top, that mostly means new rooflines or taller structures beside the chimney. If you are planning an addition near the fireplace wall, tell us, and we will check the cap against the manual before the plans are final.

How every fitting is leak checked

Each fitting on the supply is checked before the insert is used. The installation manual names the methods: a listed combustible gas detector, a noncorrosive leak detection fluid or another approved method. It adds a warning that should never need repeating: no open flame.

The check happens while the connection is still exposed, before the surround and trim close off access. Any fitting that shows a problem is remade and checked again, so the connections were proven where they can still be reached.

Common gas insert questions in Lake Mann Estates

Still weighing it up? Read these, then book the free visit in Lake Mann Estates.

Do I need a new liner for a gas insert?

Yes. A direct-vent insert uses its own liners, one for exhaust and one for combustion air, running from the insert to a cap at the chimney top. They come from the vent system named in its manual.

What happens to my old damper?

It is locked fully open or removed, as the insert manual directs, so the liners can pass through. The gap around the liners is then closed with the material the manual allows.