Vent-free fireplace repair done by the manual in Stoneybrook East

Local vent-free fireplace specialists in Stoneybrook East who find the cause first and never defeat a safety device to keep a fire going.

  • Licensed & insured
  • Locally run
  • Family owned and operated
  • Same-day service available
4.8 out of 5 from 736 reviews
  • Google
  • Yelp
  • Facebook

Your ventless fireplace inspection in Stoneybrook East, point by point

Our Stoneybrook East technicians test each of these at the fireplace itself, with your manual open beside them.

  1. Room volume measured against the rated Btu input
  2. Screen, hood and glass door arrangement checked
  3. Inlet pressure compared with the model's range
  4. Written findings with repair and code items on separate lines

Inside a ventless fireplace service call in Stoneybrook East

Read these before the visit and the conversation with our Stoneybrook East crew goes faster.

Pilot that drops out when the knob is released

Lighting steps on a vent-free log set are exact. One manual asks you to keep the control knob pressed for 30 seconds after the pilot lights, and it lists a knob pressed too briefly, a knob not pressed fully and an equipment shutoff valve left partly closed as reasons the pilot goes out.

Those are quick to rule out, and our technicians walk you through them on the first visit. If the pilot still refuses to hold, the search moves to the thermocouple, the pilot or the valve, and your written estimate names which.

Glowing embers in the right amount

Where a maker allows glowing embers at all, they go only where it says. One log set manual places rock wool embers on the front portion of the burner only, in a single layer torn into dime-size pieces, and says the total must never exceed the amount supplied with the burner.

It also says all old loose material must come off before new embers go on. Our technicians clear the burner, reapply embers to the diagram and check the flame, and that work carries our workmanship warranty.

The water a vent-free fireplace adds to the room

A gas flame gives off water vapor as it burns, and with no vent that moisture stays in the room. One maker puts the figure at about one ounce of water for every 1,000 Btu of input per hour, and recommends the heater as supplemental heat for a room rather than the main heat for a house.

That manual also says a dehumidifier may help where humidity is high, and that too little ventilation air can let mildew form. We check room size and air supply so moisture stays a minor side effect.

Ticking sounds after the fire starts or stops

Metal expands as a vent-free burner heats and contracts as it cools, and that can make a clicking or ticking sound. One manual calls this common with most heaters and suggests calling a qualified service technician only if the noise is excessive.

We listen for the difference between that ordinary sound and a loose part or failing valve. Most owners are relieved to learn the noise is normal, and hearing it from us during a free inspection costs nothing.

Caring for the cabinet and air passageways

Owner care on a vent-free unit is modest. One manual says to clean the air passageways with a vacuum cleaner or pressurized air, and to wipe the cabinet exterior with a soft cloth dampened in a mild soap and water mixture.

Anything deeper, including the pilot, burner and controls, belongs to a qualified service person. Our technicians show you the owner tasks during the visit so the fireplace stays clean between services.

Common vent-free questions in Stoneybrook East

No sales pitch here, only answers from our Stoneybrook East specialists, and a free inspection when you want one.

How big does the room need to be for a ventless fireplace?

Section 621.5 of the Florida fuel gas code limits unvented heaters to 20 Btu per hour per cubic foot of the space. Manuals also use 50 cubic feet per 1,000 Btu per hour of all appliances in the space to decide whether it is confined. We run both calculations during the free inspection.

Why do my windows fog when the ventless fireplace runs?

A gas flame gives off water vapor as it burns, and with no vent that moisture stays in the room. One troubleshooting chart ties condensation on windows to too little combustion and ventilation air. The room volume and its openings need rechecking.

Request your free estimate