A free inspection in Wedgewood Groves covers the ODS pilot, the burner, the logs and the room air, and every finding comes in writing.

  • Licensed & insured
  • Locally run
  • Family owned and operated
  • Same-day service available
4.8 out of 5 from 736 reviews
  • Google
  • Yelp
  • Facebook

Four checks from your Wedgewood Groves vent-free visit

Checked on the free inspection in Wedgewood Groves, with the numbers shared before you decide.

  1. ODS pilot flame compared with the manual's pattern
  2. Log placement matched to the model's diagram
  3. Room volume measured against the rated Btu input
  4. Shutdown tested after any safety part repair

Ventless gas fireplace repair, the way we do it in Wedgewood Groves

Pulled from the manuals and code sections our Wedgewood Groves technicians work from on every vent-free job.

Why the Florida code requires an ODS on vent-free units

Section 621.6 of the Florida Building Code, Fuel Gas, requires every unvented room heater to carry an oxygen-depletion safety shutoff. It has to shut off the gas to the main burner and the pilot when the room's oxygen drops to the level the manufacturer specifies, and the code sets a floor below which that level may not go.

So the ODS is never treated as optional hardware. When one fails, our specialists replace it with the assembly listed for your model and gas type, then test the shutdown before the fireplace goes back into service.

A yellow tip on the ODS pilot flame

A healthy ODS pilot burns blue. One manual explains that a yellow tip on the pilot flame points to dust and dirt inside the pilot assembly, and it shows a small pilot air inlet hole about 2 inches back from where the flame leaves the assembly.

With the unit off and cool, we clear that inlet the way the maker describes and relight to compare the flame. You watch the change yourself, and the inspection that finds it costs nothing.

Aftermarket blowers and heat exchangers

Adding a blower to push more heat into the room is tempting. Vent-free manuals forbid a blower insert, heat exchanger insert or any accessory not approved for the heater, and one maker explains that drafts from a blower fitted inside the fireplace may cause sooting.

Some fireboxes offer a listed blower kit mounted beneath the unit. We tell you whether yours does, and we take out an unapproved blower before any other repair, since it can undo the fix.

Checking that every burner port lights

One maker's annual checklist asks the service person to verify the flame pattern and log placement, and to confirm that all ports ignite and cross over smoothly from the rear burner to the front.

Ports that light late or not at all point to blockage or damage. Our technicians watch the crossover on every visit and clean or replace the burner as the manual directs, with the part and the reason written down.

Ticking sounds after the fire starts or stops

Metal expands as a vent-free burner heats and contracts as it cools, and that can make a clicking or ticking sound. One manual calls this common with most heaters and suggests calling a qualified service technician only if the noise is excessive.

We listen for the difference between that ordinary sound and a loose part or failing valve. Most owners are relieved to learn the noise is normal, and hearing it from us during a free inspection costs nothing.

Questions Wedgewood Groves owners ask about vent-free logs

Plain answers first, and a free visit in Wedgewood Groves whenever you want the fireplace checked.

Can a vent-free fireplace go in a bedroom?

Generally no. Section 303.3 of the Florida fuel gas code allows only a single wall-mounted unvented heater of 10,000 Btu per hour or less in a bedroom, with an oxygen depletion shutoff and enough room volume. The vent-free log set and firebox manuals we use say never to install them in a bedroom or bathroom.

How big does the room need to be for a ventless fireplace?

Section 621.5 of the Florida fuel gas code limits unvented heaters to 20 Btu per hour per cubic foot of the space. Manuals also use 50 cubic feet per 1,000 Btu per hour of all appliances in the space to decide whether it is confined. We run both calculations during the free inspection.