Vent-free gas fireplace service in Lake Mary Jane

Tell us what your vent-free fireplace is doing, and our Lake Mary Jane technicians will find the cause on a free visit.

  • Licensed & insured
  • Locally run
  • Family owned and operated
  • Same-day service available
4.8 out of 5 from 736 reviews
  • Google
  • Yelp
  • Facebook

The vent-free checks behind your Lake Mary Jane estimate

The ODS pilot gets the first look in Lake Mary Jane, then the burner, the logs and the room around them.

  1. Ignitor, electrode, cable and battery tested
  2. Logs checked for cracks, chips and loose pin fits
  3. Openings to adjoining rooms and outdoors noted
  4. Fireplace or firebox listing for vent-free use confirmed

Ventless gas fireplace repair, the way we do it in Lake Mary Jane

Why our Lake Mary Jane technicians check the room as carefully as the burner.

Delayed ignition and a burner that backfires

A burner that lights late, or pops and backfires while running, needs attention. One maker ties delayed ignition to low manifold pressure or a clogged orifice, and ties backfiring to a clogged or damaged orifice, a damaged burner or a damaged gas regulator.

We shut the unit off, let it cool and inspect the burner and orifice first. A damaged burner is replaced with the maker's listed part, and our 100% satisfaction guarantee stands behind the repair you approve.

Matching the log set to the firebox size

Each vent-free log set ships with minimum firebox dimensions. One maker lists its 18 inch set as needing a firebox at least 24 inches high, 14 inches deep, 28 inches wide at the front and 20 inches at the rear, with wider front and rear figures for its 24 inch set.

A firebox manual also warns against installing a heater in a box that misses the heater's minimum size. Our specialists measure yours against the chart for the set you own and record the numbers in your service file.

Yearly service for a ventless gas fireplace

Vent-free manufacturers agree on the schedule. The heater should be inspected before use and at least once a year by a professional service person, with more frequent cleaning where carpet, bedding or pet hair adds lint.

A yearly visit from our team covers the ODS pilot, the burner and orifice, log placement, clearances and the room air check. Your written record lists what we cleaned, what we tested and anything that needs attention.

A vent-free fireplace that has been under water

Every vent-free manual we use gives the same instruction. Once any part of the appliance has been under water, it stays off until a qualified service technician has inspected it and swapped out every control system part and gas control that was submerged.

Water inside a gas valve cannot be dried out and trusted. Our specialists list each wet control part for replacement with the maker's listed components, and the fireplace stays off until that work is complete.

The service history page in your manual

Pages for recording appliance service appear in some vent-free manuals, and one maker gives the record two full pages. A filled-in history tells the next technician what was cleaned, replaced and adjusted, and when.

Our technicians complete that record after every visit, or leave a written one when the manual is missing. Keep it with the manual near the fireplace, where the next person will find it.

Ventless fireplace answers from our Lake Mary Jane team

Short answers from our Lake Mary Jane technicians. Call with anything we have not covered.

How big does the room need to be for a ventless fireplace?

Section 621.5 of the Florida fuel gas code limits unvented heaters to 20 Btu per hour per cubic foot of the space. Manuals also use 50 cubic feet per 1,000 Btu per hour of all appliances in the space to decide whether it is confined. We run both calculations during the free inspection.

Can vent-free logs go in a prefab fireplace?

Only when that factory-built fireplace was tested, listed and labeled for unvented use under UL 127, as section 621.7 of the Florida fuel gas code requires. One log set manual adds that it must not go in a factory-built unit whose instructions say it was not tested with unvented logs.