Gas fireplace venting pros serving Storey Park
The vent is part of your fireplace's listing. Our pros repair it with listed parts, test the burn and leave you the record.
- Licensed & insured
- Locally run
- Family owned and operated
- Same-day service available
What our Storey Park crew measures at the vent cap
These checks decide whether a vent run is right for your fireplace, and our Storey Park crew writes each result down before any work.
- Firestops and wall passes at each penetration
- Rise or level run of horizontal pipe against the manual
- Roof penetration, storm collar and flashing
- B-vent height above the roof and above the draft hood
What goes into a sound vent run in Storey Park
The points below shape the vent repair we recommend in Storey Park, and each one lands in your estimate.
Horizontal runs with the wrong pitch
Horizontal vent pipe is not simply run flat. One direct-vent manual's troubleshooting table lists an improperly pitched horizontal run as a reason flames die out, and it tells the installer to check for an upward rise of 1/4 inch per foot and never run the pipe level or downhill.
The same manual gives different rules for different pipe types and layouts, so our crew checks which rule applies to your run before measuring. The finding goes in your estimate with the section of pipe it concerns.
Planning a deck or screen room near the vent
A deck built near a sidewall cap needs the cap at least 12 inches above its surface, and one maker allows a cap under a deck only when the space below is fully open on at least two sides. A screen room or enclosed porch can put the cap inside the new space entirely.
Our crew checks the plan against your fireplace manual before the builder starts. If the vent has to move, it is cheaper to know now than after the framing is up.
Propane fireplaces and the tank outside
Propane units add a few rules of their own. One direct-vent manual says propane supply tanks must be located outdoors and never inside any structure, and it advises against tanks smaller than 100 pounds capacity to prevent performance problems.
Tank sizing and placement belong to your propane supplier. Our technicians note what they see and tell you when a performance complaint may trace back to the supply rather than the vent or the fireplace.
Natural gas or propane on the rating plate
Every gas fireplace is built for the gas named on its rating plate. One direct-vent manual says its unit is not convertible to another gas unless the maker's approved conversion kit is used.
A fireplace running on the wrong gas behaves badly no matter how good the vent is. Our pros confirm the gas type on the plate against the supply before any vent diagnosis, since that check takes a minute and rules out a costly wrong turn.
Testing the fireplace after vent work
A vent repair is finished only when the fireplace runs well on it. After the work, our technicians light the unit, watch the flame against the manual's description and let it run long enough to see a steady burn and a normal shutdown.
Any gas connection that was disturbed is leak tested with a soap solution or an approved leak test spray, as manuals direct, and never with an open flame. You see the fireplace running before we leave.
Other work in Storey Park
-
Chimney Flashing Repair Repair the connection between chimney and roof. Learn more
-
Wood-Burning Fireplace Insert Installation Fit a wood insert to a suitable existing fireplace. Learn more
-
Fireplace Repair and Service Make the fireplace work for your home again. Learn more
-
Chimney Repair A sound chimney starts with the right repair. Learn more
-
Chimney Leak Repair Find the entry point before choosing the repair. Learn more
What people in Storey Park ask about fireplace vents
Weighing a vent repair? Start with these answers, and remember the vent inspection in Storey Park costs nothing.
Can I plant shrubs or build a deck near the vent cap in Storey Park?
Check the distances first. One maker keeps bushes, fences, sheds and decks at least 24 inches from the front of the cap and allows a cap under a deck only when it is open on two sides. We measure your layout for free.
What does a B-vent fireplace need from its vent?
Type B pipe listed to UL 441, a listed cap and enough height. The Florida fuel gas code asks for the vent to end at least 5 feet above the draft hood, and the manual adds limits on offsets, elbows and slope.