A free inspection in Hibiscus covers the ODS pilot, the burner, the logs and the room air, and every finding comes in writing.

  • Licensed & insured
  • Locally run
  • Family owned and operated
  • Same-day service available
4.8 out of 5 from 736 reviews
  • Google
  • Yelp
  • Facebook

Four checks from your Hibiscus vent-free visit

Every result lands on your written estimate in Hibiscus, repair items on one line and code items on another.

  1. Flame height and color compared with the manual
  2. Drafts from fans, returns and doors observed
  3. Gas connections leak tested with soap solution
  4. Fireplace or firebox listing for vent-free use confirmed

Ventless gas fireplace service notes for Hibiscus

Each topic below can show up on an estimate in Hibiscus, so here is what it means.

Reading the pilot flame against the thermocouple

On many vent-free units the pilot flame has to wrap the thermocouple to hold the gas valve open. One manual prints the correct pattern beside a faulty one in which the flame misses the thermocouple. The thermocouple cools, and the heater shuts down.

A pilot knocked out of position, a partly blocked orifice or low gas pressure can each move that flame. Our specialists identify which one is at work before quoting a part, so you never pay for a thermocouple the fireplace did not need.

Orange flames during the first hour on new logs

New or newly reset logs can burn orange at first. One manual says the flame will be orange for about an hour on first use while the logs cure, and that slight smoking can happen early on as manufacturing residues burn off.

After a log replacement we run the set long enough to see the flame settle, then check it again. If the orange never clears, we treat it as a finding and trace the cause.

Checking that every burner port lights

One maker's annual checklist asks the service person to verify the flame pattern and log placement, and to confirm that all ports ignite and cross over smoothly from the rear burner to the front.

Ports that light late or not at all point to blockage or damage. Our technicians watch the crossover on every visit and clean or replace the burner as the manual directs, with the part and the reason written down.

Protecting the valve during gas pipe pressure tests

When the gas piping in a house is pressure tested, the vent-free heater needs protecting. One manual says to disconnect the heater and its shutoff valve for tests above 1/2 psig, and to close the heater's shutoff for tests at or below that, because higher pressure damages the heater regulator.

After any gas pipe work, we check that the fireplace was isolated and that its regulator and valve still behave. If they do not, we explain the damage and the replacement part in writing.

Moving a ventless fireplace to another room

What suits one room may be wrong for another. A new space for a vent-free unit has to pass the room volume and air rules, the clearances in the manual and the limits on bedrooms and bathrooms, and a wall that fits the unit physically has passed none of those yet.

Before a move, our team runs every check against the new location and sends the results in writing. Relocation work and any repair are priced as separate lines.

Questions Hibiscus owners ask about vent-free logs

Plain answers first, and a free visit in Hibiscus whenever you want the fireplace checked.

How big does the room need to be for a ventless fireplace?

Section 621.5 of the Florida fuel gas code limits unvented heaters to 20 Btu per hour per cubic foot of the space. Manuals also use 50 cubic feet per 1,000 Btu per hour of all appliances in the space to decide whether it is confined. We run both calculations during the free inspection.

Can I add embers or lava rock to vent-free logs?

Only as your manual allows. One maker limits rock wool embers to a single layer on the front of the burner and keeps lava rock on the fireplace floor. Other manuals ban added logs, pine cones, vermiculite and rock wool because they cause sooting.